nur im Hochschulnetz
Refine
Year of publication
Document Type
- Bachelor Thesis (295)
- Article (205)
- Book (61)
- Conference Proceeding (58)
- Part of a Book (56)
- Other (36)
- Master's Thesis (29)
- Working Paper (6)
- Doctoral Thesis (3)
- Report (1)
Language
- German (543)
- English (207)
- Multiple languages (1)
Keywords
- Soziale Arbeit (20)
- Inklusion (13)
- Sozialarbeit (13)
- Pflege (12)
- Bildung (11)
- Alter (9)
- Altenpflege (8)
- Behinderung (8)
- Gesundheitsförderung (8)
- Kinder (7)
Institute
- Institut für Gesundheits-und Pflegewissenschaften (IGP) (23)
- Institut für nachhaltige Energietechnik und Mobilität (INEM) (17)
- Virtual Automation Lab (VAL) (3)
- Weitere Projekte der Fakultät SABP (3)
- Institut für Automobilmanagement (IAM) (1)
- Institut für Change Management und Innovation (CMI) (1)
- Labor Kunststofftechnik (LKT) (1)
Our study is dedicated to a composite, which, in fact, is a mixture of two thermoelastic micropolar bodies. We formulate the mixed initial boundary value problem in this context and define the domain of influence for given data. For any solution of the mixed problem we associate a measure and prove a second-order differential inequality for it. Based on the maximum principle for the heat equation and on the second-order differential inequality, we establish an estimate which proves that the thermal and the mechanical effects, at large distance from the domain of influence, are dominated by an exponential decay.
Effect of voids in a heat-flux dependent theory for thermoelastic bodies with dipolar structure
(2020)
The objective of this study is to investigate the influence of veneering technique (hand-layering vs. milling) on the fracture resistance of bi-layer implant-supported zirconia-based hybrid-abutment crowns. Mandibular molar copings were anatomically designed and milled. Copings were then veneered by hand-layering (HL) (n = 20) and milling using the Cad-On technique (LD) (n = 20). Crowns were cemented to zirconia hybrid-abutments. Ten samples of each group acted as a control while the remaining ten samples were subjected to fatigue in a chewing simulator. Crowns were loaded between 50 and 100 N for 1.2 million cycles under simultaneous temperature fluctuation between 5 and 55 °C. Crowns were then subjected to static load a to fracture test. Data were statistically analysed using the one-way ANOVA. Randomly selected crowns from each group were observed under scanning electron microscopy to view fractured surfaces. Study results indicate that during fatigue, LD crowns had a 100% survival rate; while HL crowns had a 50% failure rate. Fracture resistance of LD crowns was statistically significantly higher than that of HL crowns at the baseline and after fatigue (p ≤ 0.05). However, fatigue did not cause a statistically significant reduction in fracture resistance in both LD and HL groups (p > 0.05). Copings fractured in the LD crowns only and the fracture path was different in both LD and HL groups. According to the results, it was concluded that milled veneer implant-supported hybrid-abutment crowns exhibit significantly higher fracture resistance, and better withstand clinical masticatory loads in the posterior region compared to the hand-layered technique. Also, fatigue application and artificial aging caused no significant strength reduction in both techniques. Clinical significance: Different veneering techniques and materials (hand-layering or milling) act differently to clinical forces and environment and may be prone to early chipping during service. Therefore, practitioners are urged to consider the appropriate veneering protocol for posterior implant-supported hybrid-abutment restorations.
Mobilitätshilfen sind allgegenwärtig und existenziell für Menschen, die aufgrund von Krankheit und Pflegebedürftigkeit in ihren Alltagsbewegungen und -fortbewegungen eingeschränkt sind. Mobilität steht in einem direkten Zusammenhang zur Selbstständig-keit und Selbstbestimmung im Alltag. Für viele pflegebedürftige Menschen sind Mobili-tätshilfen entscheiden dafür, ob sie ihren Alltag (wieder) selbst gestalten können. Dabei müssen sie sich innerhalb und außerhalb von Räumen ganz unterschiedlichen Heraus-forderungen stellen. Teilhabe am sozialen, möglicherweise auch am beruflichen Leben wird für viele Betroffene erst dann möglich, wenn die unterschiedlichen Mobilitätshilfen aufeinander und auf die jeweiligen Aktivitäten abgestimmt sind. Für Angehörige und für Pflegefachpersonen stellt sich täglich die Frage, mit welchen Mobilitätshilfen eine siche-re und angemessene Unterstützung möglich ist. Dabei gilt es, die Ausstattung mit Hilfen dem aktuellen Mobilitätsprofil der Betroffenen anzupassen; die Folgen von Über- oder Unterversorgung mit Mobilitätshilfen kann für die Betroffenen gravierende negative Folgen haben!
We consider the mixed initial-boundary value problem in the context of the
Moore-Gibson-Thompson theory of thermoelasticity for dipolar bodies. We consider the case of heat conduction with dissipation. Even if the elasticity tensors
are not supposed to be positively defined, we have proven both, the uniqueness
and the instability of the solution of the mixed problem. In the case that the mass
density and the thermal conductivity tensor are positive, we obtain the uniqueness
of the solution using some Lagrange type identities.
Zustimmung zum Schwangerschaftsabbruch bei einsichtsfähiger Minderjähriger nicht erforderlich
(2020)
In our study, we consider the linear mixed initial boundary value problem for a porous elastic body having a dipolar structure. The equations that describe the elastic dipolar deformations are coupled with the equations which describe the evolution of the voids by means of certain coefficients. Our main result proves the continuous dependence of solutions for the mixed problem with regard to the coefficients which perform this coupling. Using an adequate measure, we can evaluate the continuous dependence by means of some estimate regarding the gradient of deformations and the gradient of the function that describes the evolution of the voids.
This study is concerned with the linear elasticity theory for bodies with a dipolar structure. In this context, we approach transient elastic processes and the steady state in a cylinder consisting of such kind of body which is only subjected to some boundary restrictions at a plane end. We will show that at a certain distance d=d(t), which can be calculated, from the loaded plan, the deformation of the body vanishes. For the points of the cylinder located at a distance less than d, we will use an appropriate measure to assess the decreasing of the deformation relative to the distance from the loaded plane end. The fact that the measure, that assess the deformation, decays with respect to the distance at the loaded end is the essence of the principle of Saint-Venant.
Laser powder-bed fusion (LPBF) has significantly gained in importance and has become one of the major fabrication techniques within metal additive manufacturing. The fast cooling rates achieved in LPBF due to a relatively small melt pool on a much larger component or substrate, acting as heat sink, result in fine-grained microstructures and high oversaturation of alloying elements in the α-aluminum. Al-Si-Mg alloys thus can be effectively precipitation hardened. Moreover, the solidified material undergoes an intrinsic heat treatment, whilst the layers above are irradiated and the elevated temperature in the built chamber starts the clustering process of alloying elements directly after a scan track is fabricated. These silicon-magnesium clusters were observed with atom probe tomography in as-built samples. Similar beneficial clustering behavior at higher temperatures is known from the direct-aging approach in cast samples, whereby the artificial aging is performed immediately after solution annealing and quenching. Transferring this approach to LPBF samples as a possible post-heat treatment revealed that even after direct aging, the outstanding hardness of the as-built condition could, at best, be met, but for most instances it was significantly lower. Our investigations showed that LPBF Al-Si-Mg exhibited a high dependency on the quenching rate, which is significantly more pronounced than in cast reference samples, requiring two to three times higher quenching rate after solution annealing to yield similar hardness results. This suggests that due to the finer microstructure and the shorter diffusion path in Al-Si-Mg fabricated by LPBF, it is more challenging to achieve a metastable oversaturation necessary for precipitation hardening. This may be especially problematic in larger components.
Das Interesse der Industrie an additiv gefertigten Bauteilen steigt z unehmend, wobei mit zunehmendem Verständnis der statischen Kennwerte nunmehr der Fokus in Richtung der dynamischen Festigkeiten wandert. Deswegen werden Einflussparameter auf die Lebensdauer und potenzielle Nachbearbeitungsmethoden untersucht und analysiert. Ein großer Einfluss ist dabei der Oberflächengüte und den durch Rautiefen initiierten Kerbeffekten zuzuschreiben. Deswegen werden unterschiedliche Methoden zur Verbesserung der Oberflächengüte untersucht. Dabei werden die Verfahren Laserpolieren, elektrochemisches Polieren und Hartmetallkugelstrahlen und deren Auswirkung auf Oberflächengüte sowie Härte untersucht. Für das elektrochemische Polieren werden die Proben in einer Perchlorsäure für 90 s bei 32 V und maximal 10 A poliert. Das Hartmetallkugelstrahlen wird mit einem UFS 100 Strahlmittel bei einem Druck von 4 bar und einer Strahldauer von 10 s ausgeführt. Anschließend werden Wöhlerlinien für die unterschiedlichen Zustände mittels Umlaufbiegeversuch ermittelt, welche mit Referenzwerten analysierter konventioneller Proben verglichen werden. Des Weiteren werden die Bruchflächen analysiert. Die Untersuchungen ergaben ein hohes Optimierungspotenzial der additiv gefertigten Proben bei einer Verdichtung der Oberfläche sowie einer Entfernung der Randschicht durch eine spanende Bearbeitung. Dadurch wurden höhere Zeitfestigkeiten als mit konventionell gefertigten Proben erreicht.
Development of environment-friendly natural fiber composites has been a recent trend. However, due to the fact that natural fibers permit high level of moisture absorption from the surroundings, it can lead to weak bindings and degradation of composite properties. This paper presents an experimental study on the dynamic performance of flax fiber composite beams manufactured at different relative humidity (RH) levels. Five types of flax fiber-reinforced composite materials were made under different RH values, i.e., dry, 35%, 50%, 70%, and 95% RH, and beam samples were prepared using the composite. Impact hammer testing was conducted to measure the natural frequencies and damping of the beams. It was found that for the first three modes, while the resonant frequencies are very close for most samples, there is a clear drop of frequencies for the composite fabricated at 95% RH. Along with an increase of the RH level, the damping ratios for all the three modes have reported a slight increase, but the variation is not significant.
The characteristics and atomic mechanisms (physics) of processes of thermal desorption of deuterium from isotropic graphite at temperatures 700–1700 K are considered.
Metal additive manufacturing of dental prostheses consisting of cobalt−chromium−tungsten (Co−Cr−W) alloys poses an alternative to investment casting. However, metal additive manufacturing processes like Laser Powder‐Bed Fusion (LPBF) can impact the elastic constants and the mechanical anisotropy of the resulting material. To investigate the phase compositions of mechanically different specimens in dependence of their postprocessing steps (e. g. heat treatment to relieve stress), the current study uses X‐ray Diffraction (XRD), Electron BackScatter Diffraction (EBSD), and Transmission Electron Microscopy (TEM) for phase identification. Our studies connect plastic deformation of Remanium star CL alloy with the formation of the hexagonal ϵ‐phase and heat treatment with the formation of the D024‐phase, while partially explaining previously observed differences in Young's moduli.
Laser powder bed fusion has become one of the major techniques within metal additive manufacturing, especially when delicate structures and high geometric accuracy are concerned. Lately, the awareness of the material-specific macroscopic anisotropy has risen and led to widespread investigations on the static mechanical strength. However, little is known about the fracture behavior of the layer-wise fabricated metal components and their affinity of crack propagation between consecutive layers, which is particularly important for aluminium–silicon alloys containing embrittled zones in double-irradiated areas. A recent study indicated that there is a significant drop in fracture toughness in case the crack growth direction is parallel to the layering. To investigate this matter further and to shed light on the fracture toughness behavior in the range of a 0°–45° angle offset between the crack growth direction relative to the layering, notched samples with varying polar angles were subjected to mode I fracture toughness testing. Our results indicate that the fracture toughness is an almost-stable characteristic up to a mismatch of about 20° between the crack propagation path and the layering, at which point the fracture toughness decreases by up to 10%.
Laser powder-bed fusion has become one of the most important techniques in additive manufacturing. For guaranteeing the possibility of manufacturing highly specialized and advanced components, currently intensive research is carried out in this field. One area of this research is the material-specific macroscopic anisotropy, which is investigated in our work by comprehensive static mechanical experiments. The material which was tested within this study was the precipitation-hardenable AlSi10Mg alloy, with the focus on installation space orientation. Tensile and compression tests were performed, the results for the Young's modulus in compressive loading exceeded the previously known values of this material in tensile loading and achieved values of up to 79.8 GPa. As a result of this investigation, a chemical spectroscopic analysis was undertaken and from the actual chemical composition, a relative density of 99.86% of the samples was determined.